Prosoft Ethernet Communication Gateway PLX31-EIP-SIE

ProSoft Technology’s EtherNet/IP™ to Siemens® Industrial Ethernet communication

gateway allows high-speed bi-directional data transfers between EtherNet/IP™

enabled controllers or devices and Siemens® S7-200. S7-300. S7-400. S7-1200. and

S7-1500 PACs.

In addition, the gateway includes several features, including data prioritization, that

allow for simplified integration, reduced commissioning time and optimized

performance.

Features

 Data prioritization: Multiple I/O connections allow you to set RPIs for status and/or control data, optimizing Ethernet bandwidth.

 Includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time.

 Includes a SD card slot (SD card optional) for storing configuration files. This can be used for disaster recovery.

 ProSoft Discovery Service: This utility allows your PC to see the gateway and change its default IP address without being on the

same subnet.

 Secure module configuration via module switch (v1.04 and greater).

 Up to 10.000 16-bit registers can be used to exchange large amounts of data.

Prosoft PROFIBUS DPV1 Master Communication Module PS69-DPM Configuration

DPV0 Services Supported

 Fail Safe Mode

 Global Control

 Sync and Freeze

 Watchdog

DPV1 Services Supported

 Read Request

 Write Request

 Alarm Indication

 Extended Device Diagnostics

Configuration

The Configuration for the PS69-DPM is done with our next generation configuration tool PROSOFT.fdt. The configuration software

and communication DTM are included with the module allowing easy configuration of the Master module and network slave devices.

The DTM can be used in any FDT compatible software container.

The configuration is transferred via the serial diagnostic interface and stored in the FLASH memory of the PS69-DPM module.

General Specifications

 Single Slot – 1769 backplane compatible

 The module is recognized as an Input/Output module and has access to processor

memory for data transfer between processor and module

 Ladder Logic is used for data transfer between module and processor. Sample

ladder file included.

 Supports all CompactLogix and MicroLogix 1500 LRP Controllers except 1769

L23E-QBFC1B, 1769-L16x, and 1769-L18x

Prosoft PROFIBUS DPV1 Master Communication Module PS69-DPM

The PS69 PROFIBUS DP Master module expands the functionality of ’s

CompactLogix / MicroLogix family of processors to include PROFIBUS. This

module supports both I/O control and messaging, thus integrating DPV0 and DPV1

functionality into CompactLogix / MicroLogix.

The PS69-DPM is a CompactLogix / MicroLogix compatible, PROFIBUS certified

module, which enables controllers to communicate with a PROFIBUS network. The

configuration and diagnostic of the PROFIBUS system is done via the serial

diagnostic interface of the module using the System Configuration tool . The data

exchange between controller and module is done via the I/O process data image

using CompactLogix / MicroLogix backplane technology.

DPV0 Services Supported

 Fail Safe Mode

 Global Control

 Sync and Freeze

 Watchdog

DPV1 Services Supported

 Read Request

 Write Request

 Alarm Indication

 Extended Device Diagnostics

Prosoft AN-X4-AB-DHRIO EtherNet/IP™ to Remote I/O or DH+ Gateway Bridge Mode

Remote I/O Scanner

This operating mode allows users to replace their existing Remote I/O PLC with a ControlLogix or

CompactLogix PAC without having to replace existing racks of I/O.

Build new controller programs without interrupting existing controls, minimizing downtime

Supports up to 32 racks of Remote I/O

Supports all Remote I/O baud rates (57.6. 115.2. and 230.4 K baud), and Remote I/O addressing 0 to 76 octal

Auto-Configuration utility discovers baud rate and maps discrete I/O, reducing configuration errors

Remote I/O Adapter

This operating mode allows PLC’s on Remote I/O to share data with a newer ControlLogix or CompactLogix PAC’s.

This mode also allows a ControlLogix processor to monitor Block Transfer and I/O data on an active Remote I/O network without occupying a drop.

Supports up to 16 EtherNet/IP I/O connections to a Logix processor

Supports any combination of Remote I/O rack addressing

Auto-configures rack addressing and baud rate

Bridge Mode

This operating mode allows the module to listen to all messages on an Ethernet network and

use its “BridgeIP” mapping to forward the messages out of the DH+/BH port.

The messages received on the DH+/BH port can be forwarded to the devices connected to its Ethernet port.

Allows the use of existing Blue Hose cabling for EtherNet/IP communication:

I/O to Controllers

HMI to SCADA

Programming Controllers via PC

Support for up to 64 AN-X4-BRG, each on different Ethernet network

DH+ mode supports up to 230k Baud Rate

Blue Hose mode supports up to 460K Baud Rate

Prosoft AN-X4-AB-DHRIO EtherNet/IP™ to Remote I/O or DH+ Gateway HMI

HMI

This operating mode allows legacy PanelViews to be upgraded to a PanelView Plus 6 or PanelView Plus 7 via EtherNet/IP.

No changes to PLC code required

Supports up to 8 PanelViews on the same network.

Drive

This operating mode supports upgrading legacy Allen Bradley drives on Remote I/O to new EtherNet/IP-enabled drives.

No changes to PLC code required

Supports up to 4 EtherNet/IP drives

Configurable with ¼, ½, and full rack addressing

Supports all PowerFlex drives on EtherNet/IP.

Flex I/O Scanner

This operating mode allows PLC’s on Remote I/O to connect to and control 1794-AENT EtherNet/IP Flex adapters.

Designed to replace obsolete 1794-ASB adapters

Supports up to 16 EtherNet/IP connections

Each adapter and rack of discrete counts as a single connection. Each analog module counts as a single connection.

Prosoft AN-X4-AB-DHRIO EtherNet/IP™ to Remote I/O or DH+ Gateway

The AN-X4-AB-DHRIO Gateway is designed to help customers initiate a phased migration

approach to replacing or upgrading legacy PLC’s, HMI’s, Drives, or Flex I/O adapters.

These solutions can be achieved by selecting the corresponding operating mode during the initial configuration.

The AN-X4-AB-DHRIO has a built-in webserver to view diagnostics, current configuration,

upload configuration files, and set the operating mode. It is also DIN Rail Mountable.

Specifications

DH+ to EtherNet/IP™

1/ The operating mode acts as a bridge between an EtherNet/IP and a DH+ network.

Programming terminals, and/or processors on an EtherNet/IP network can access legacy processors on a DH+ network

Download to a PLC5 or SLC through RSLinx

Configured through web browser

Supports all DH+ baud rates (57.6. 115.2. and 230.4 K baud).

2/ The operating mode helps the communication between an Ethernet-Based processor with legacy processors on a DH+ network.

Support gathering data without changing existing PLC or SLC hardware

DH+ to Modbus TCP

This operating mode allows Modbus TCP Clients to access the PLC data from stations on a Data Highway Plus Network.

The Modbus TCP server supports up to 128 connections

Modbus Input and Output Registers are mapped to the PLC/SLC files for each station

Modbus TCP Unit/Slave ID data is mapped to the Data Highway Plus Station

Prosoft AN-X2-ABRIO-EIPSCN Remote I/O to Ethernet/IP Scanner Module Cabling and Termination

Ethernet Configuration

AN-X can be configured:

• to use a static (unchanging) IP address

• to obtain its IP address from a DHCP server

• to use the fixed link-local address 169.254.42.84

AN-X modules are shipped with the link-local address 169.254.42.84.

Unless you have control of the DHCP server, in most applications you will assign the

AN-X a static IP address. Otherwise the DHCP server may assign a different IP address

each time AN-X powers up, and any software that accesses the AN-X module would have

to be reconfigured.

If you are using multiple AN-X modules, connect and configure one at a time, since

initially they will all be set to the same link-local IP address.

The AN-X2-ABRIO-EIPSCN module connects a controller on remote I/O such as a

PLC-5 to scan I/O modules on Ethernet.

Before you can use the AN-X2-ABRIO-EIPSCN, you must configure its network

properties on Ethernet.

IMPORTANT!

If you are connecting AN-X to an existing Ethernet network, consult the

network administrator to obtain information about how you should

configure AN-X or to obtain a static IP address for AN-X.

Prosoft AN-X2-ABRIO-EIPSCN Remote I/O to Ethernet/IP Scanner Module Ethernet Configuration

Cabling and Termination

Follow Allen-Bradley cabling recommendations for remote I/O. Refer to Approved

Vendor List for DH, DH+, DH-485. and Remote I/O Cables, publication ICCG-2.2.

February 1996.

On the AN-X module, the connections should be line 1. shield, line 2.

Ethernet Configuration

The AN-X2-ABRIO-EIPSCN module connects a controller on remote I/O such as a

PLC-5 to scan I/O modules on Ethernet.

Before you can use the AN-X2-ABRIO-EIPSCN, you must configure its network

properties on Ethernet.

IMPORTANT!

If you are connecting AN-X to an existing Ethernet network, consult the

network administrator to obtain information about how you should

configure AN-X or to obtain a static IP address for AN-X.

Prosoft AN-X2-ABRIO-EIPSCN Remote I/O to Ethernet/IP Scanner Module Operation

AN-X2 Modes of Operation

There are two AN-X2 modes of operation:

• Maintenance mode. The AN-X2 runs the maintenance firmware at startup. It

performs diagnostics (memory tests, etc), copies any changes from the microSD card.

If there are no errors, it starts the AN-X2 in production mode.

• Production mode. This is the normal runtime mode of operation.

Prevent Electrostatic Discharge

The module is sensitive to electrostatic discharge.

WARNING!

Electrostatic discharge can damage integrated circuits or

semiconductors. Follow these guidelines when you handle the module:

• Touch a grounded object to discharge static potential

• Do not touch the connector pins

Power

AN-X requires a DC power input of anywhere from 12 to 24 VDC.

Left to right the pins on the power connector are chassis ground, negative voltage and

positive voltage.

The chassis ground should be connected.

Power consumption is 200 mA @ 12VDC or 100mA @ 24VDC.

The part number for the power connector is Phoenix MSTB 2.5/3-ST-5.08

Contact us if you need a suitable wall adapter.

Prosoft AN-X2-ABRIO-EIPSCN Remote I/O to Ethernet/IP Scanner Module Package Contents

Package Contents

• AN-X2-ABRIO module

• microSD to SD card adapter

• CD containing software and documentation

• rubber feet for desktop use

Using the MicroSD Card

The AN-X2 microSD card stores configuration data and firmware.

The are no restrictions on the size or speed of the card. The format must be FAT-16 or

FAT-32.

An adapter is provided so you can insert the microSD card in an SD slot in your

computer.

The card must be present while the AN-X2 is running.

WARNING!

Do not remove the card while the AN-X2 is powered on!

If the AN-X2 is inaccessible from Ethernet because of its settings, you can remove the

card and edit the file config.txt. Refer to page 12 for details.

Reinsert the card in the slot at the back of the AN-X2. with the pins facing up.

WARNING!

If you remove the card to edit the configuration file, push the card in

straight or the card might fall inside the case and you will have to

disassemble the AN-X2 to retrieve it .